Features
- Four traces may be simultaneously displayed in ALT-sweep
- Five vertical display modes: CH1, CH2, Dual, Add, Subtract
- Vertical mode triggering for displaying 2 unrelated signals
- Trigger hold-off circuit for synchronizing complex waveforms
- Sweep speeds to 2nS/ Div
- 12kV acceleration voltage for bright displays of low duty cycle signals
- Z axis input
- TV Synchronization for either line or field patterns
- 20MHz bandwidth limit switch for triggering signals in a noisy environment
Product Information
100 MHz 2Ch. Dual Time Base with Alt Mag.
Specifications
Vertical Amplifier (CH 1 and CH 2)
- Sensitivity : 5 mV/Div to 5 V/ Div in 7 calibrated steps, (X5 Mag 1mV/ Div to 1 V/ Div)
- Accuracy : ± 3% (± 5% in X5 Mag)
- Bandwidth (-3dB) : DC to 100MHz
- Rise Time : £ 3.5 ns, X5 Mag: 20MHz Bandwidth: £ 17 ns
- Input Impedance : 1MW + 25 pF
- Input Coupling : AC-Gnd-DC
- Invert Channel : CH2
- Display Modes : CH1, CH2, Add, Subtract, Dual (Alt/Chop)
- Maximum Input Voltage : 400V (DC or AC peak)
- CH1 Signal Output : 20mV into 50W
Horizontal Sweep
- Timebase A – Sweep Time : 50ns/Div to 0.2 s/Div in 21 calibrated steps (1-2-5)
- Timebase A – X10 Mag : 5ns/Div to 20ms/ Div
- Timebase A – Accuracy : ± 3% (± 5% in X10 Mag)
- Timebase A – Hold Off : Continuously adjustable to > 2X sweep time
- Timebase B – Sweep Time : 50ns/Div to 10µ s/ Div in 8 steps (1-2-5)
- Timebase B – Accuracy : ± 3%
- Timebase B – Delay Time : Continuously variable from 0.2µ s to 2s
- Timebase B – Delay Modes : Continuous or triggered
- Timebase B – Sweep Displays : A, B, A alt B, B triggered, X-Y
X-Y Mode
- CH1-X axis, CH2-Y axis Sensitivity : Same as CH1 vertical amplifier
- Bandwidth (X-axis) : DC to 2MHz
- Phase Error : £ 3° DC to 10kHz
Triggering
- Trigger Modes : Auto, Normal, TV-V, TV-L
- Source : Int. CH2, line ext.
- Coupling : AC
- Slope : Positive or negative
- Trigger Sensitivity :
- Int (DC to 10MHz) : 0.5 Div
- Int (10MHz to 100MHz) : 1.5 Div
- Ext (DC to 10MHz) : 200mV
- Ext (10MHz to 100MHz) : 500mV
- TV (Int) : 1 Div Min
- TV (Ext) : 1V P-P
- External Trigger Input : Impedance: 1MW + 20 pF
- Maximum Input Volts : 400V DC or AC peak
Z Axis Modulation
- Sensitivity : ± 5V P-P Intensity increases with a negative going voltage input
- Bandwidth (-3dB) : DC to 2MHz
- Input Impedance : Approx. 2 KW
Calibrator Signal
- Voltage : 0.5V ± 3% P-P 1kHz Square Wave
- Duty Cycle : Approx. 50%
CRT
- Type : 6″ rectangular CRT with internal graticule. (1 Div = 1cm)
- Acceleration Voltage : 12 kV
General Specification
- Power Requirements : AC Input Voltage: 100V, 120V, 220V, 240V selectable
- Frequency : 50/60Hz
- Power Consumption : 55W
- Operating Temperature : 0 to 40° C at 35% to 85% relative humidity
- Dimensions : 5.25″ H × 12.67″ W × 14.5″ D
- Weight : 24 lbs.
- Supplied Accessories : Manual, 1 AC Power cord, (2) X10 Probes.